Canton Generating Set
Standard of Genset Features
Cummins water cooled Diesel Engine, Oil and fuel filter fitted, Water separator. Lube-oil drain valve fitted
Electric starter & Charger alternator 12/24 v D.C.
Electric Governor
Normal duty air filter
Single bearing alternator, class H/H
Standard voltage 400/230 volts 50 hz
Exciter/Voltage reg - Torque Match as Standard
STeel base frame with A/V mounting,
Engine, Alternator, Chassis & COntrol Box
Radiator
Packing under shrunk plastic film
Operation & Maintenance manual
Standard set of labels
The emission of its major products meet China National Standards, US Standards, and the Ueropean Standards for highway and off-highway diesel engine.
Characterized by its robust power, fuel economy, goo reability, durability, safety and environment friendly factors, the products are highly appraised by customers at home and abroad.
CUmmins engine are commited to making the world a brighter and better place to live.
Generator Set Performance
Voltage Regulation
Maintains voltage output to within 1.0%. at any power factor between 0.8 and 1.0. At any variations from no-load to full-load. At any variations from Cold to Hot. At speed droop variations up to 4.5%.
Frequency Regulation
Isochronous under varying loads from no load to 100% full load when electronic governor is fitted.
Random Frequency Variation
Will not exceed 0.25% of its mean value for constant loads - no load to full load.
Waveform
Total harmonic distortion open circuit voltage waveform in the order of 1.8%. Three-phase balanced load in the order of 5.0%.
Telephone Influence Factor (TIF)
TIF better than 50.
THF to BS 4999 Part 40 better than 2%.
Alternator Temperature Rise
Class H insulation.
Radio Interference
In compliance with BS 800 and VDE levels G and N.
Generator Set Options
Fuel Options
Fuel tank (for silent type are standard)
Exhaust Options
Exhaust Silencer - Industrial In-Line
Exhaust Bellows
Exhaust Silencer - Residential, In-Line
Installation Kit - Industrial Silencer
Installation Kit - Residential Silencer
Voltage Connections
240/416V, 230/400V, 220/380V, 127/220V, 115/200 V, 110/190V.
Miscellaneous Options
3 pole or 4 pole Circuit Breaker
Optional Set mounted starting batteries
Coolant Heater 240V
Battery Charger 240, 5A or 10A
Automatic Transfer Switches
Auto Start, AMF Module, Automatic Transfer Switches
Engine Specification
Engine is designed and manufactured by Cummins.
Type
Water Cooled, Four cycle, naturally aspirated / turbo-charged and aftercooled (around type).
Construction
Two valves per cylinder, forged steel crankshaft and connecting rods, cast iron block.
Fuel System
12/24 volt fail safe actuator. Spin-on paper element fuel filters with fuel pump injection system with integral electonic governor. Dual flexible fuel lines and connectors. Standard fuel water separator.
Filters
Air cleaner with dry element.
Spin-on full flow lube oil filter.
Cooling
40 Celcius ambient temperature standard
Stone guard. Drain Tap.
Prime Power
Prime Power is available continuously during the period of power outage in a variable load application. Variable load should not exceed a 70% average of the prime power rating during any 24 hour period. A 10% overload capability is available for a period of 1 hour within a 12 hour period of operation.
Standby Power
The Standby Power is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. In installations served by unreliable utility sources (where outages last longer or occur more frequently). Where operation is likely to exceed 200 hour per year, the prime power rating should be applied. The Standby Power rating is only applicable for emergency and standby applications where the generator set serves as the back up to the normal utility source.
All ratings are based on the following reference conditions:
At 1500 rpm, 50 Hz, 0,8 PF (lagging), 3 Phase, 4 Poles, 230/400 Volt, IP 23, Class H Insulation, Ambient Temperature 27 C : Altitude above sea level 150 meters; relative humidity 60%. Alternator Option : LEROY SOMER / MARATHON. Control Panel System : DEEP SEA Electronic Plc.
Operation Environment:
The ideal operation environment for generator set is an ambient temperature of below 40 C and below an altitude of 1525 m. With every 300 m increase of altitude beyond 1525 m, output power will decrease by 4%. With every 11 C increase of temperature above 40 C, output power will decrease by 2%.
DSEULTRA
Deep Sea ELectronic PLC



Click link below to download Canton Generating Set Specification.
| Attachment | Size |
|---|---|
| canton_spec.pdf | 21.38 KB |